Worthington, and patented in 1844. Mr. Worthington's first pump was
designed for feeding boilers. His first water works engine was built for
the city of Savannah, Ga., and erected in 1854. The second engine, which
was the duplicate of the Savannah engine, was erected at the city of
Cambridge, Mass., in the year 1856, and was guaranteed to deliver 300,000
gallons in twenty-four hours to an altitude of 100 feet. It had a high
pressure cylinder 12 inches in diameter, placed within a low pressure
cylinder 25 inches in diameter; the low pressure piston being annular.
The double acting water plunger was 14 inches in diameter, and worked
directly from the high pressure piston rod; the stroke of pistons and
plunger being 25 inches. This engine was tested in 1860, with the result
of a duty equal to 70,463,750 foot pounds per 100 pounds of coal.
Subsequently, a test made by Mr. Frederick Graff, of Philadelphia (long
prominently connected with the Philadelphia Water Department), and the
late Erastus W. Smith, of New York, developed a duty of 71,278,486 foot
pounds per 100 pounds of coal, which long remained the best record in the
United States. In 1863, Mr. Worthington brought out at Charleston, Mass.